Part Number | HMISCU6B5 |
Manufacturer | Schneider Electric |
Type | HMIs |
Warranty | 2 Year |
Product weight | 0.512 kg |
Range of product | Magelis SCU |
Product or component type | Small touch HMI controller |
Display size | 3.5 inch |
Display type | Backlit LED colour TFT LCD |
Pixel resolution | 320 x 240 pixels QVGA |
Touch panel | Analogue |
Backlight lifespan | Lifespan: 50000 hours with 65000 colours |
Brightness | 16 levels via touch panel |
View angle horiz x vert | 60° left |
60° right | |
40° top | |
60° bottom | |
Character font | ASCII |
Supply | External source |
[Us] rated supply voltage | 24 V at 20.4...28.8 V DC |
Immunity to microbreaks | <= 10 ms |
Inrush current | <= 30 A |
Power consumption | 15 W |
Local signalling | No indicator |
Number of pages | Limited by internal memory capacity |
Software designation | SoMachine |
Operating system | Magelis |
Processor name | CPU RISC |
Processor frequency | 333 MHz |
Memory description | 128 MB flash memory, type: NAND |
128 kB internal data storage memory, type: FRAM | |
128 MB application run memory, type: DRAM | |
Integrated connection type | 1 Ethernet TCP/IP, connector type: RJ45 |
1 serial link, communication ports RS485/RS232, connector type: RJ45, transmission rate: <= 115.2 | |
kbits/s | |
1 USB (V2.0) port, connector type: mini B USB | |
1 USB (V2.0) port, connector type: USB A | |
CANopen master bus, connector type: SUB-D 9 | |
Realtime clock | Built-in |
Downloadable protocols | Modbus |
Modbus TCP/IP | |
CANopen | |
Fixing mode | By 1 nut - diameter: Ø 22 mm, mounting on: 1...6 mm thick panel |
Enclosure material | PC/PBT |
Shock resistance | 147 m/s² (duration=11 ms) conforming to IEC 60068-2-27 on DIN rail |
294 m/s² (duration=6 ms) conforming to IEC 60068-2-27 on panel mounting |
Vibration resistance | +/- 3.5 mm (f=5...9 Hz) conforming to IEC 60068-2-6 |
1 gn (f=9...150 Hz) conforming to IEC 60068-2-6 | |
Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 8 kV, air discharge conforming to IEC 61000-4-2 |
Electrostatic discharge immunity test - test level: 6 kV, contact discharge conforming to IEC | |
61000-4-2 | |
Susceptibility to electromagnetic fields - test level: 10 V/m, 80 MHz...3 GHz conforming to IEC | |
61000-4-3 | |
Electrical fast transient/burst immunity test - test level: 2 kV, power lines conforming to IEC 61000-4-4 | |
Electrical fast transient/burst immunity test - test level: 1 kV, between analogue I/O and operating | |
voltage conforming to IEC 61000-4-4 | |
Electrical fast transient/burst immunity test - test level: 2 kV, relay wires conforming to IEC 61000-4-4 | |
Electrical fast transient/burst immunity test - test level: 1 kV, Ethernet line conforming to IEC | |
61000-4-4 | |
Electrical fast transient/burst immunity test - test level: 1 kV, COM line conforming to IEC 61000-4-4 | |
Electrical fast transient/burst immunity test - test level: 1 kV, CAN line conforming to IEC 61000-4-4 | |
Surge immunity test - test level: 2 kV, power supply (common mode) conforming to IEC 61000-4-5 | |
Surge immunity test - test level: 1 kV, power supply (differential mode) conforming to IEC 61000-4-5 | |
Surge immunity test - test level: 1 kV common mode, digital I/O conforming to IEC 61000-4-5 | |
Surge immunity test - test level: 0.5 kV differential mode, digital I/O conforming to IEC 61000-4-5 | |
Conducted RF disturbances - test level: 10 V, 0.15...80 MHz conforming to IEC 61000-4-6 | |
Conducted emission - test level: 150 kHz...30 MHz conforming to EN 55011 | |
Radiated emission - test level: 30 MHz...1 GHz conforming to EN 55011 | |
Discrete input number | 2 for fast input (normal mode) conforming to IEC 61131-2 Type 1 |
6 for digital input conforming to IEC 61131-2 Type 1 | |
Discrete input voltage | 24 V DC discrete input logic:sink or source (positive/negative) |
Number of common point | 1 for fast input (HSC mode) |
1 for digital input | |
Discrete input current | 7.83 mA for fast input |
5 mA for digital | |
Input impedance | 4.7 kOhm |
2.81 kOhm | |
Sensor power supply | 15...28.8 V DC, voltage (state 1): >= 15 V, current (state 1): >= 5 mA, voltage (state 0): <= 5 V, |
current (state 0): <= 1.5 mA | |
15...28.8 V DC, voltage (state 1): >= 15 V, current (state 1): >= 2.5 mA, voltage (state 0): <= 5 V, | |
current (state 0): <= 1 mA | |
Configurable filtering time | 0 ms no filter (none) |
0.004...0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)) | |
3...12 ms integrator (none/run/stop) | |
Input frequency | 100 kHz for fast input (encoder mode) - control type A/B |
100 kHz for fast input - control type single phase | |
100 kHz for fast input - control type pulse/direction | |
Cable length | 10 m shielded cable for fast input |
100 m shielded cable for digital input | |
50 m unshielded cable for digital input | |
Connection pitch | 3.5 mm |
Overvoltage protection | With |
Isolation between channels and | 500 V DC |
Isolation between channels | None |
Discrete output number | 2 fast output (normal mode), output logic: source |
6 digital output, output logic: source | |
Discrete output voltage | 24 V DC (voltage limit: 19.2...28.8 V) with transistor discrete output(s) |
24 V DC (voltage limit: 5...30 V) with relay discrete output(s) | |
220 V AC (voltage limit: 100...250 V) with relay discrete output(s) | |
Input/Output number | 2 for fast input, terminal(s): FI0...FI1 |
2 for fast output, terminal(s): FQ0...FQ1 | |
6 for digital input, terminal(s): DI0...DI5 | |
6 for digital output, terminal(s): DQ0...DQ5 | |
Discrete output current | 300 mA, response time 2 ms for fast output (normal mode) |
50 mA, response time 2 ms for fast output (PWM or PTO mode) | |
2 A (current per output common:4 A), response time 5 ms with opening contact for digital output | |
2 A (current per output common:4 A), response time 2 ms with closing contact for digital output | |
Insulation resistance | > 10 MOhm between the I/O and internal logic |
> 10 MOhm between power supply and earth | |
Output frequency | <= 100 kHz for fast output (PTO mode) |
<= 1 kHz for fast output (PWM mode) | |
Absolute accuracy error | +/- 0.1 % of full scale of cyclic ratio 1...99% for fast output (PWM or PTO mode) |
1 % of full scale of cyclic ratio 1...99% for fast output (PWM or PTO mode) | |
+/- 5 % of full scale of cyclic ratio 10...90% for fast output (PWM or PTO mode) | |
+/- 10 % of full scale of cyclic ratio 20...80% for fast output (PWM or PTO mode) | |
+/- 15 % of full scale of cyclic ratio 30...70% for fast output (PWM or PTO mode) | |
Analogue input number | 2 for analog input |
2 for RTDs | |
Analogue input range | 0...20 mA/4...20 mA - resolution: 12 bits, input impedance: 250 Ohm (tolerance: +/- 1 %) |
-10...+10 V or 0...10 V - resolution: 12 bits + sign, input impedance: >= 1 MOhm | |
Analogue input type | RTD at - 200...600 °C - resolution: 16 bits temperature probe: Pt 100/Pt 1000 |
RTD at - 50...200 °C - resolution: 16 bits temperature probe: Ni 100/Ni 1000 | |
RTD at - 200...760 °C - resolution: 16 bits (thermocouple J) | |
RTD at - 240...1370 °C - resolution: 16 bits (thermocouple K) | |
RTD at 0...1600 °C - resolution: 16 bits (thermocouple R) | |
RTD at 200...1800 °C - resolution: 16 bits (thermocouple B) | |
RTD at 0...1600 °C - resolution: 16 bits (thermocouple S) | |
RTD at - 200...400 °C - resolution: 16 bits (thermocouple T) | |
RTD at - 200...900 °C - resolution: 16 bits (thermocouple E) | |
RTD at - 200...1300 °C - resolution: 16 bits (thermocouple N) | |
Analogue output number | 2 resistive load for 12 bits + sign |
Analogue output range | 0...20 mA/4...20 mA (> 300 Ohm) for open-circuit |
-10...10 V/0...10 V (> 2 kOhm) for short-circuit | |
Height | 74.95 mm |
Width | 128 mm |
Depth | 102 mm |
MRO Electric repairs CNCs, PLCs, Servo/Spindle Drives, Motors, Amplifiers, VFDs, HMIs, and more, most of which can be repaired in only 3-5 days.
MRO can restore your failed HMISCU6B5 to remanufactured condition and save you up to 75% compared to buying new. We offer standard repair pricing to ensure you the best value for your repair.
Our certified technicians use rigorous testing procedures to ensure your parts are restored to fully functioning condition. Our team proudly stands behind all repairs by providing a minimum 2-year warranty.
Our technicians have vast experience with most manufacturers and models. In addition to this HMISCU6B5 we also repair drives, motors, PLCs and more, so if you don’t see the model you need, please contact us.
If you are interested in getting credit for your faulty HMISCU6B5, just let us know, and we can issue you an RMA to send it in as an exchange. Our exchange program provides you with savings and keeps us stocked for the next time you need anything.
Want it shipped tomorrow?
Ask about exchanging your faulty HMISCU6B5 for credit when ordering from MRO Electric
Can a HMISCU controller be used with no display?
Schneider Electric products are manufactured in France and are designed for Material handling, packaging, and textile machines usage. They come with a 2-year warranty from MRO Electric. We also carry HMIs from other manufacturers such as Modicon and ABB.
Check out the rest of our Schneider Electric product line. Whether it's using our online instant quote feature, giving us a call at (800) 691-8511, or emailing us at sales@mroelectric.com, we strive for customer satisfaction first. This means lower prices and better service for you. For more products like HMISCU6B5, take a look at more from our HMIs line. If your current unit has gone bad, take advantage of our Core Exchange program for the most inexpensive route. You can learn more about this program on our FAQ page here. We offer a repair service on all of our HMISCU6B5 products that keep your downtime to a minimum. To stay up to date on manufacturer news, as well as access any of our datasheets, manuals, or other documentation, we suggest you take a look at our blog.