Robotics Applications

Fanuc 911 RAM PARITY ERROR Troubleshooting

Fanuc 911 RAM PARITY ERROR Troubleshooting

MRO Electric and Supply maintains a comprehensive stock of new and used FANUC CNC and FANUC Robots parts. If you need a FANUC replacement part, please call 800-691-8511 or email sales@mroelectric.com.

Last week we had a customer who was running an RNC 16 STAR 1990 vintage machine which failed so he decided to replace the main A16B-1010-0280 motherboard. His original problem was that he was receiving a 401 [VRDY Off] Error which then led to a 911 Error. When he replaced the A16B-1010-0280 motherboard, the machine would go directly to the 911 Error.

The first thing we checked for was to make sure that he transferred over all of the EEPROM modules from his original board to the replacement board, which he did. Since that wasn’t the issue, we double checked on the 911 Error, which shows as a RAM PARITY ERROR in the manual. The main cause of this error is an issue with the memory in the unit, which is caused by the memory board failing or losing the parameters in the system.

To check to see if the memory board was causing it or not, you can turn the control off, reset it, and delete the parameters. If this clears the alarm, the control would come up with a different series of servo alarms meaning that the parameters need to be reloaded. If the Fanuc 911 Error comes back it would mean that there is a problem with the memory board which needs to be replaced. Before trying any of this, be sure to confirm that you have all of the parameters saved so you can load them back in. Check out our article on IT and Robotics here.

Once the 911 Error was cleared, the customer was able to load the parameters back on to get the machine up and running.

Joe Kaminski

Joe Kaminski is an industrial automation specialist at MRO Electric. He has a background in industrial engineering and supply chain management. Joe has worked in the automation industry for over 10 years providing support to some of the largest companies in the world. For more info, visit www.mroelectric.com.

Share
Published by
Joe Kaminski

Recent Posts

Legal and Safety Requirements Regarding Arc Flashes

Arc flash incidents are among the most dangerous hazards in the electrical industry, posing serious…

2 days ago

Understanding an Arc Flash

Understanding an Arc Flash An arc flash stand as one of the most dangerous electrical…

3 weeks ago

Distributed Control System (DCS) Explained

A Distributed Control System (DCS) is a type of automated industrial control system (ICS) used…

3 weeks ago

The Effects of Dirty Power on Electronics

The Effects of Dirty Power In today's tech-driven world, many of our most valuable devices…

1 month ago

The Most Popular U.S. College Mascots

The game is almost over, and your team is losing. You can feel the crowd’s…

2 months ago

Warning Signs of a Failing Servo Motor

Whether we want to admit it or not, our entire world economy hinges on the…

2 months ago