Last week we had a customer who was running an RNC 16 STAR 1990 vintage machine which failed so he decided to replace the main A16B-1010-0280 motherboard. His original problem was that he was receiving a 401 [VRDY Off] Error which then led to a 911 Error. When he replaced the A16B-1010-0280 motherboard, the machine would go directly to the 911 Error.
The first thing we checked for was to make sure that he transferred over all of the EEPROM modules from his original board to the replacement board, which he did. Since that wasn’t the issue, we double checked on the 911 Error, which shows as a RAM PARITY ERROR in the manual. The main cause of this error is an issue with the memory in the unit, which is caused by the memory board failing or losing the parameters in the system.
To check to see if the memory board was causing it or not, you can turn the control off, reset it, and delete the parameters. If this clears the alarm, the control would come up with a different series of servo alarms meaning that the parameters need to be reloaded. If the Fanuc 911 Error comes back it would mean that there is a problem with the memory board which needs to be replaced. Before trying any of this, be sure to confirm that you have all of the parameters saved so you can load them back in. Check out our article on IT and Robotics here.
Once the 911 Error was cleared, the customer was able to load the parameters back on to get the machine up and running.
End of Year Maintenance As the year comes to a close, it’s the perfect time…
Allen-Bradley Programmable Logic Controllers (or PLC) remain widely used in industrial automation. Programming their PLCs…
The game is almost over, and your team is losing. You can feel the crowd’s…
Whether you’re loyal to the classic, double stuf, or thin OREOs, the addicting cookies always…
Arc flash incidents are among the most dangerous hazards in the electrical industry, posing serious…
Understanding an Arc Flash An arc flash stand as one of the most dangerous electrical…